How to Compare Space Velocity in Catalyst Quotations
Two catalyst quotations can show different space velocities for the same duty. The difference may reflect the calculation basis rather than catalyst performance. Before using the figures to compare offers, establish what each supplier has calculated and which conditions apply. For purchasing teams and traders, the practical next step is to put that basis in the enquiry and ask suppliers to respond against it. Space velocity relates a feed rate to a stated catalyst or reactor quantity. GHSV, LHSV and WHSV can all be expressed in h⁻¹, so the unit alone does not identify the calculation. For a fixed feed rate under the same definition, a lower space velocity corresponds to a larger volume or mass in the stated denominator. This relationship alone does not establish catalyst activity or actual gas residence time. A calculation using reference gas volume should not be presented as a measured contact time. If a supplier uses a carbon-based figure, request its formula, carbon accounting, streams included and units. Do not assume it has the same definition as GHSV or as another supplier's carbon-based value. The following hypothetical calculation illustrates reporting bases. Assume the same physical feed and catalyst loading throughout: Here, Nm³ is defined at 0°C and 101.325 kPa absolute. The calculation assumes ideal-gas behaviour; gas volumes are reference-volume equivalents, not actual reactor flow rates. The agreed denominator is the 10 m³ catalyst volume, excluding the separate support layer. The temperature conversion uses absolute temperature: 30,000 × 288.15 / 273.15 ≈ 31,647 m³/h. Results are rounded. The first three rows describe the same physical feed and loading using different reporting bases. The final row deliberately illustrates a denominator error. A wet-basis figure of 4,500 h⁻¹ and a dry-basis figure of 3,000 h⁻¹ can therefore describe the same loading in this example; the larger number does not demonstrate better catalyst performance. For conversions between mass and volume bases, obtain the relevant flow, catalyst quantity and density data where needed. Ask the supplier and the end user's technical team to verify the assumptions before using a converted figure for selection. Once the basis is aligned, ask each supplier to relate its proposed value to the same feed analysis, flow range, operating conditions, reactor and required outlet specification. Identify whether the value is a design reference, a recommended operating range or a maximum limit. Then compare the offered catalyst quantity and scope, any written performance conditions, and the proposed acceptance method. Keep estimated service life separate from a contractual guarantee. A space-velocity figure by itself is not a complete technical offer. Send the same checklist to each supplier. If a supplier uses another basis, request both calculations with their assumptions clearly identified. Please quote against the basis below and confirm each item in writing: Attached: [available datasheet, operating records, required quantity and delivery requirements]. If documents contain different values or labels, ask which revision applies to the proposed supply and obtain a consistent written clarification. Keep each item marked as proposed or technically agreed. Traders should pass technical questions to the end user's process contact. An indicative conversion may help organise a comparison, but its assumptions and unresolved points should remain visible to the technical reviewers. Missing information can stay as “to be confirmed” in an initial enquiry. When sending an enquiry to SYAMCAT, include the documents available, required quantity and delivery requirements. Highlight the space-velocity basis and any points that need clarification.Identify the type of space velocity
Type Calculation basis Details to confirm GHSV — gas hourly space velocity Gas volume flow divided by the stated bed or reactor volume Gas reference temperature and pressure, dry or wet basis, and the volume counted in the denominator. LHSV — liquid hourly space velocity Liquid volume flow divided by the stated bed or reactor volume Liquid volume measurement conditions, streams included and the denominator definition. WHSV — weight hourly space velocity Feed mass flow divided by catalyst mass Feed streams included and the condition or measurement basis of the catalyst mass. See how the calculation basis changes the number
Reporting or calculation basis Gas volume flow on the stated basis, m³/h Denominator, m³ Calculated figure, h⁻¹ Dry gas at 0°C reference 30,000 10 3,000 Dry gas at 15°C reference, same absolute pressure and molar flow 31,647 10 3,165 Total gas including the steam equivalent, at 0°C reference 45,000 10 4,500 Incorrect denominator for the agreed catalyst-only basis: adding the separate inert support layer 30,000 11 2,727 Compare offers against the same duty
Use one enquiry checklist
Resolve open points before selection