Two catalyst quotations can show different space velocities for the same duty. The difference may reflect the calculation basis rather than catalyst performance. Before using the figures to compare offers, establish what each supplier has calculated and which conditions apply.

For purchasing teams and traders, the practical next step is to put that basis in the enquiry and ask suppliers to respond against it.

Identify the type of space velocity

Space velocity relates a feed rate to a stated catalyst or reactor quantity. GHSV, LHSV and WHSV can all be expressed in h⁻¹, so the unit alone does not identify the calculation.

TypeCalculation basisDetails to confirm
GHSV — gas hourly space velocityGas volume flow divided by the stated bed or reactor volumeGas reference temperature and pressure, dry or wet basis, and the volume counted in the denominator.
LHSV — liquid hourly space velocityLiquid volume flow divided by the stated bed or reactor volumeLiquid volume measurement conditions, streams included and the denominator definition.
WHSV — weight hourly space velocityFeed mass flow divided by catalyst massFeed streams included and the condition or measurement basis of the catalyst mass.

For a fixed feed rate under the same definition, a lower space velocity corresponds to a larger volume or mass in the stated denominator. This relationship alone does not establish catalyst activity or actual gas residence time. A calculation using reference gas volume should not be presented as a measured contact time.

If a supplier uses a carbon-based figure, request its formula, carbon accounting, streams included and units. Do not assume it has the same definition as GHSV or as another supplier's carbon-based value.

See how the calculation basis changes the number

The following hypothetical calculation illustrates reporting bases. Assume the same physical feed and catalyst loading throughout:

  • Dry gas: 30,000 Nm³/h.
  • Steam: an ideal-gas reference-volume equivalent of 15,000 Nm³/h.
  • Packed catalyst bulk volume: 10 m³, plus a separate 1 m³ inert support layer.

Here, Nm³ is defined at 0°C and 101.325 kPa absolute. The calculation assumes ideal-gas behaviour; gas volumes are reference-volume equivalents, not actual reactor flow rates. The agreed denominator is the 10 m³ catalyst volume, excluding the separate support layer.

Reporting or calculation basisGas volume flow on the stated basis, m³/hDenominator, m³Calculated figure, h⁻¹
Dry gas at 0°C reference30,000103,000
Dry gas at 15°C reference, same absolute pressure and molar flow31,647103,165
Total gas including the steam equivalent, at 0°C reference45,000104,500
Incorrect denominator for the agreed catalyst-only basis: adding the separate inert support layer30,000112,727

The temperature conversion uses absolute temperature: 30,000 × 288.15 / 273.15 ≈ 31,647 m³/h. Results are rounded.

The first three rows describe the same physical feed and loading using different reporting bases. The final row deliberately illustrates a denominator error. A wet-basis figure of 4,500 h⁻¹ and a dry-basis figure of 3,000 h⁻¹ can therefore describe the same loading in this example; the larger number does not demonstrate better catalyst performance.

For conversions between mass and volume bases, obtain the relevant flow, catalyst quantity and density data where needed. Ask the supplier and the end user's technical team to verify the assumptions before using a converted figure for selection.

Compare offers against the same duty

Once the basis is aligned, ask each supplier to relate its proposed value to the same feed analysis, flow range, operating conditions, reactor and required outlet specification. Identify whether the value is a design reference, a recommended operating range or a maximum limit.

Then compare the offered catalyst quantity and scope, any written performance conditions, and the proposed acceptance method. Keep estimated service life separate from a contractual guarantee. A space-velocity figure by itself is not a complete technical offer.

Use one enquiry checklist

Send the same checklist to each supplier. If a supplier uses another basis, request both calculations with their assumptions clearly identified.

Please quote against the basis below and confirm each item in writing:

  1. Space velocity: type, formula and unit.
  2. Feed basis: streams counted, including whether steam or recycle gas is included.
  3. Reference conditions: gas temperature and absolute pressure, dry or wet basis; liquid measurement conditions where relevant.
  4. Catalyst quantity: mass or volume, its definition and whether separate inert or support layers are counted.
  5. Applicable duty: feed analysis, normal/minimum/maximum flow, operating temperature and pressure, reactor information and outlet requirements.
  6. Status of the value: design reference, recommended range or maximum limit.
  7. Supporting documents: datasheet revision number and date.
  8. Alternative basis: provide both calculations if your preferred basis differs from this enquiry.
  9. Open points: list assumptions, deviations and missing information separately.

Attached: [available datasheet, operating records, required quantity and delivery requirements].

Resolve open points before selection

If documents contain different values or labels, ask which revision applies to the proposed supply and obtain a consistent written clarification. Keep each item marked as proposed or technically agreed.

Traders should pass technical questions to the end user's process contact. An indicative conversion may help organise a comparison, but its assumptions and unresolved points should remain visible to the technical reviewers. Missing information can stay as “to be confirmed” in an initial enquiry.

When sending an enquiry to SYAMCAT, include the documents available, required quantity and delivery requirements. Highlight the space-velocity basis and any points that need clarification.

Two people reviewing documents at a table
Laptop displaying a technical drawing on a desk

Paperwork and a calculator on an office desk

Are you looking for a reliable manufacturer of down home textile products?

We can quickly provide customers with market analysis, technical support and customized services.
Through continuous technological innovation, SYAMCAT provides catalyst solutions for ammonia, methanol, hydrogen, refinery, and related chemical processes.
Phone+86-533-2802131E-mailmarketing@syamcat.com
Contact Our Catalyst Team
SYAMCAT is a professional manufacturer of synthetic ammonia catalysts with over 30 years of catalyst experience and history,Through continuous technological innovation, we offer catalyst solutions for ammonia production.If you would like to learn more or are in search of a manufacturer for synthetic ammonia catalysts for your company, please feel free to contact us.
*Email
Name
Phone
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
follow us
subscription